ACCT(2) — Stardent Computer Inc. (System Calls)
NAME
acct − enable or disable process accounting
SYNOPSIS
int acct (path)
char ∗path;
DESCRIPTION
acct is used to enable or disable the system process accounting routine. If the routine is enabled, an accounting record will be written on an accounting file for each process that terminates. Termination can be caused by one of two things: an exit call or a signal [see exit(2) and signal(2)]. The effective user ID of the calling process must be super-user to use this call.
path points to a pathname naming the accounting file. The accounting file format is given in acct(4).
The accounting routine is enabled if path is non-zero and no errors occur during the system call. It is disabled if path is zero and no errors occur during the system call.
acct will fail if one or more of the following are true:
[EPERM] The effective user of the calling process is not super-user.
[EBUSY] An attempt is being made to enable accounting when it is already enabled.
[ENOTDIR] A component of the path prefix is not a directory.
[ENOENT] One or more components of the accounting file path name do not exist.
[EACCES] The file named by path is not an ordinary file.
[EROFS] The named file resides on a read-only file system.
[EFAULT] Path points to an illegal address.
SEE ALSO
DIAGNOSTICS
Upon successful completion, a value of 0 is returned. Otherwise, a value of −1 is returned and errno is set to indicate the error.
September 29, 2021