arithex.diag(8) — Stardent Computer Inc. (November 15, 1988)
NAME
arithex.diag∗ − check that the system correctly recovers from exceptions generated by the arithmetic logic.
DESCRIPTION
This test deliberately generates arithmetic exceptions, checks that the exception condition is registered, then checks that the proper corrective action is taken.
DETAILS
none required.
BOARDS THAT MUST BE INSTALLED
This test requires a CPU card, and at least one memory card to be present in the system, and a known good I/O board for downloading the test.
SPECIAL COMMAND LINE PARAMETERS
None
MENU ITEMS SPECIFIC TO THIS TEST
arith1
arith2
arith3
arith4Separate parts of the overall arithmetic exception recovery test.
allRun all of the above
INTERPRETING THE ERROR CODES
The only error type reported here is that the actual value did not equal the expected value. The error reporting includes the source line in the verilog test script the actual value read and the expected value. The script must be examined to determine what type of testing is being performed. This error could indicate an error either in the load pipe circuitry, the memory, the ETLB circuitry, the vector register memory, the arithmetic logic units, or anywhere in between.
September 29, 2021