SAMPLE STROKE(3P) — Kubota Pacfic Computer Inc. (29 February 1991)
NAME
SAMPLE STROKE − sample the current measure of a stroke device
SYNOPSIS
C Syntax
void
psample_stroke ( ws, dev, view_ind, stroke )
Pintws;workstation identifier
Pintdev;stroke device number
Pint∗view_indOUT view index
Ppoint_list∗stroke;OUT locator postion
Required PHIGS Operating States
(PHOP, WSOP, ∗, ∗)
DESCRIPTION
Purpose
Use SAMPLE STROKE to sample the current measure of the specified stroke device without waiting for input from the operator. The device must be in SAMPLE mode. See SET STROKE MODE and INITIALIZE STROKE for more information.
C Input Parameters
wsWorkstation identifier. An integer specifying the workstation with which the specified stroke device is associated.
devThe device number of the stroke device to be sampled. See the Available Devices section of INITIALIZE STROKE for a description of the available devices.
C Output Parameters
view_ind
The view index used to transform the Device Coordinate (DC) positions to World Coordinate (WC) points.
strokePpoint_list is defined in phigs.h as follows:
typedef struct {
Pintnum_points;
Ppoint∗points;
} Ppoint_list;
num_points is the number of points in points.
points is the array of Ppoint structures specifying the points in WC. This array must be allocated by the calling program and the array pointer assigned to this field before calling this function. The array must be at least as large as the buffer of the STROKE device. This buffer size is set when the device is initialized. Ppoint is defined in phigs.h as follows:
typedef struct {
Pfloatx;/∗ x coordinate ∗/
Pfloaty;/∗ y coordinate ∗/
} Ppoint;
Execution
SAMPLE STROKE samples the specified stroke device. The device must be in SAMPLE mode. See SET STROKE MODE and INITIALIZE STROKE for more information.
When a device is set to SAMPLE mode, a measure process is created for the device and the device is activated. When SAMPLE STROKE is called, the current value of the measure process for the specified device is retrieved without waiting for further input from the operator.
A STROKE device measure consists of a list of WC points and a view index. The points correspond to positions on the workstation selected by the operator. The view index is the index of the view used to transform these positions from DC to WC. See INITIALIZE STROKE and SET VIEW TRANSFORMATION INPUT PRIORITY for a description of how this view representation is determined. The workstation transformation is used to map the DC position to a Normalized Projection Coordinate (NPC) position.
Note: The 2D and 3D stroke measure processes are the same except that the 2D process discards the z coordinate. The 3D version of this function, SAMPLE STROKE 3, can be used if the value of the z coordinate is needed.
ERRORS
003Ignoring function, function requires state (PHOP, WSOP, ∗, ∗)
054Ignoring function, the specified workstation is not open
061Ignoring function, specified workstation is neither of category INPUT nor of category OUTIN
250Ignoring function, the specified device is not available on the specified workstation
252Ignoring function, the function requires the input device to be in SAMPLE mode
SEE ALSO
INITIALIZE STROKE (3P)
SET STROKE MODE (3P)
REQUEST STROKE 3 (3P)
GET STROKE (3P)
INQUIRE STROKE DEVICE STATE (3P)
SET VIEW TRANSFORMATION INPUT PRIORITY (3P)
SAMPLE STROKE 3 (3P)
September 02, 1992