Museum

Home

Lab Overview

Retrotechnology Articles

Online Manuals

⇒ dhu(4) — Ultrix-32 1.1

Media Vault

Software Library

Restoration Projects

Artifacts Sought

Related Articles

tty(4)

DHU(4)

NAME

dhu − DHU-11 communications multiplexer

SYNTAX

device dh0 at uba0 csr 0160440 vector dhurint dhuxint

DESCRIPTION

A dhu-11 provides 16 communication lines with modem control. 

Each line attached to the DHU-11 communications multiplexer behaves as described in tty(4). Input and output for each line can be set independently to run at any of 16 speeds; see tty(4) for the coding.

Bit i of flags can be specified for a dhu to say that a line is not properly connected, and that the line should be treated as hard-wired with carrier always present.  Thus specifying “flags 0x0004” in the specification of dhu0 would cause line ttyA2 to be treated in this way. 

FILES

/dev/tty[A-F][0-9a-f]
/dev/ttyd[0-9a-f]

DIAGNOSTICS

dhu%d %d: DMA ERROR.  The indicated channel failed to transfer DMA data within 21.3 microseconds of the bus request being acknowledged or there was a memory parity error.  This is often followed by a UNIBUS adapter error, which occurs most frequently when the UNIBUS is heavily loaded and when devices such as rk07’s, which monopolize the bus, are present. 

dhu%d: DIAG. FAILURE.  The dhu failed the diagnostics that run at initialization time. 

dhu%d: recv. fifo overflow.  The character input fifo overflowed before it could be serviced.  This can happen if a hard error occurs when the CPU is running with elevated priority.  Interrupts are disabled, and the system then prints a message on the console. . 

SEE ALSO

tty(4)

Typewritten Software • bear@typewritten.org • Edmonds, WA 98026